Download the current Florida Uniform Mitigation Verification Inspection Form, see what each of the nine sections covers, and find out how the new rule affects your roof-to-wall connectors.
Download the form (PDF) Call (877) 659-8354Uniform Mitigation Verification Inspection Form · Adopted by Rule 69O-170.0155, F.A.C. · 6 pages
Based on the new 1802 wind mitigation form, altering the existing connector no longer qualifies for wind mitigation credits. We must add new connectors when this condition is present.
On the form itself, Section 6 notes that all retrofit connectors or structural fasteners must meet option 3: a purpose-made connector installed per the manufacturer's specifications to reach the listed wind uplift capacity.
We don't make the rules, but we follow them. We have been completing retrofits for the past 15 years and have helped over 10,000 Floridians. If you lose your discount, call us and we will determine what it takes to be compliant under the new standards.
Call (877) 659-8354 Read about the 3rd nail rule changeThe Uniform Mitigation Verification Inspection Form records the wind-resistant features of a Florida home so your insurer can review them for possible premium discounts. Keep a copy with your insurance policy.
The inspection must be certified by a qualified inspector. Section 627.711(2), Florida Statutes, lists who may sign the form.
At least one photograph or document must accompany the form to validate each attribute marked in questions 2 through 9.
The form is valid for up to five years if no material changes are made to the structure and no inaccuracies are found.
The form notes that some items listed may not qualify for a discount. Your insurer makes that decision.
Florida Retrofits can help with the sections marked with a link.
Which version of the Florida Building Code was in force when the original permit was applied for.
Your location by design wind speed (HVHZ, Region 1, 2 or 3), based on ASCE 7-22.
Whether the main roof slope is 6:12 or greater, or less than 6:12.
Each roof covering in use, with permit dates or product approval numbers and the year installed.
Our roofing servicesThe weakest form of roof deck attachment, from nailing patterns to documented uplift resistance.
Roof deck attachmentThe weakest roof-to-wall connection: toenails, clips, single wraps, double wraps or structural.
Hurricane straps and clipsHip, flat or other roof shape, based on the share of non-hip features around the roof perimeter.
Whether a secondary water resistance layer is in place. Standard underlayment or hot-mopped felts do not qualify.
RoofingThe weakest wind-borne debris protection on windows, doors, skylights and garage doors.
Windows and doors | ShuttersSection 6 asks for the weakest roof-to-wall connection on the house. For purpose-made connectors, the form lists the substantiated wind allowable uplift capacity for each type, and site-specific documentation is required.
| Type | What it means on the form | Purpose-made connector capacity |
|---|---|---|
| A. Toenails | Truss or rafter nailed at an angle to the top plate, or connectors not installed as intended. | Other documented methods: 185 lbs. or greater |
| B. Clips | Metal connectors that do not wrap over the truss or rafter, or a wrap secured with a minimum of three nails. | 386 lbs. or greater |
| C. Single Wraps | A single strap over the truss or rafter, secured with two nails on one side and one on the other. | 535 lbs. or greater |
| D. Double Wraps | Two separate straps over the truss or rafter, or a single strap with three nails on each side. | 891 lbs. or greater |
| E. Structural | Anchor bolts structurally connected, or a reinforced concrete roof. | Not applicable |
Summary only. Read the full wording on the form, and ask your inspector how it applies to your home.
Right here. The Uniform Mitigation Verification Inspection Form, OIR-B1-1802 (Rev. 04/26), is available as a PDF at the top of this page.
The form must be certified by a qualified inspector. Section 627.711(2), Florida Statutes, lists the individuals who may sign it.
The form states that it is valid for up to five years, provided no material changes have been made to the structure and no inaccuracies are found on the form.
Based on the new 1802 wind mitigation form, altering the existing connector no longer qualifies for wind mitigation credits. New connectors must be added when this condition is present.
The existing strap lacks engineering to determine the uplift resistance.
Call Florida Retrofits at (877) 659-8354. We will determine what it takes to be compliant under the new standards.
Send us your inspection results and we will tell you what it takes to meet the new standards. Free evaluation and quote.
(877) 659-8354The form shown is OIR-B1-1802 (Rev. 04/26), adopted by Rule 69O-170.0155, F.A.C. Florida Retrofits is not an insurance company and cannot guarantee any discount. Discounts are determined by your insurer. Confirm the current form requirements with your insurer or qualified inspector. Download the form (PDF).